Operation:

The unit can be used in two ways, as an extractor fan or a trickle ventilator.

For trickle ventilator facility use snib to open slide. This allows air to move naturally between inside

and outside of window.



Bathroom Extract Fan: (Single speed fan with humidistat) 15L/s


1.   Use snib to open slide and pull cord to turn fan on, the indicator light will come on.

      2.   When switched on the Fan will run for 10 minutes then the fan will slow to a stop and enter humidity sense              mode

3.   Fan will re-start automatically should the humidity exceed determined level.

4.   To start fan running regardless of humidity, for example to extract smells, pull cord until LED dims

      then switch on again.

5.   To turn fan off pull cord once and indicator light will go out.



Kitchen Extract Fan: (Two speed fan with humidistat) 60l/s & 30l/s


  1. When the pull cord is operated the Fan will run at boost speed for 10 minutes then reduce to low speed,
  2. After a further 10 minutes the fan will stop and enter humidity sense mode
  3. The fan sequence will restart if the humidity rises above the predetermined level.
  4. To return to boost at any time , pull cord until LED dims  then pull once more.
  5. Pull cord once to switch off




IMPORTANT SAFETY NOTICE

This appliance can be used by children aged from 8 years and above and persons with reduced physical

Sensory or mental capabilities or lack of experience and knowledge if they have been given supervision

or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.

Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or

other fuel-burning appliances.